Description
The Hamilton-T1 is the first transport ventilator that combines the functionality of a fully featured ICU ventilator with the compactness and ruggedness required for transport. This combination enables you to provide optimal ventilation therapy to all patient groups during transport.
Hamilton T1 Transport Ventilator Specifications:
General
- Brand: Hamilton
- Model: T1
- Category: Ventilators
- Mounting Type: Ambulance
- Patient Age Group: Neonatal, Adult, Paediatric
- Tidal Volume: Adult/Ped: 20 to 2000 ml, Neonatal: 2 to 300 ml
- Ventilation Mode: APVcmv/(S)CMV+, APVsimv/SIMV+, PCV+, PSIMV+, DuoPAP, APRV, SPONT, ASV, NIV, NIV-ST, nCPAP, nCPAP-PC, HiFlowO2
- Brightness: The range is 10% to 100% brightness. By default, Day is set to 80%; Night is set to 40%.
- Maximum Inspiratory Flow: 260 L/min (120 L/min with 100% O2)
- Flow Trigger: Adult/Ped: 1 to 20 L/min, Neonatal: 0.1 to 5 L/min
- Oxygen Percentage: Adult/Ped: 21 to 100, Neonatal: 21 to 100
Pneumatic Performance
- Oxygen Pressure: High Pressure: 2.8 to 6 bar / 41 to 87 psi, Low Pressure: Maximum 6 bar / 87 psi
- Oxygen Connector: High Pressure: DISS (CGA 1240) or NIST, Low Pressure: Quick-coupling system, compatible with Colder Products Company (CPC) PMC series
- Air Supply: Integrated turbine
- Inspiratory Outlet (To Patient Port): Connector: ISO ID15/OD22 conical
- Expiratory Outlet (From Patient Port): Connector (on expiratory valve): ISO ID15/OD22 conical
Graphical Patient Data
- Intelligent Panel: Dynamic Lung 3, Vent Status, ASV Graph 4
- Waveform: Pressure, Volume, Flow, PCO2 1, FCO2 1, Plethysmogram2
- Trend: 1, 6, 12, 24, or 72-h5 trend data for a selected parameter or combination of parameters
- Loops: Pressure/Volume, Pressure/Flow, Volume/Flow, Volume/PCO21, Volume/FCO21
Additional Details
- Power Supply: 100 to 240 V AC ±10%, 50/60 Hz, 12 to 28 V DC (total range 10.2 to 30.3 V DC)
- Display Size: 8.4 inch (214 mm) diagonal
- Display Type: Color TFT
- Battery Backup: Typically 4 hours with one battery, 8 hours with two batteries
- Weight: 6.5 kg (14.3 lb)
- I:E Ratio: Adult/Ped: 1:9 to 4:1, Neonatal: 1:9 to 4:1
- Automatic Expiratory Base Flow: Adult/Ped: Fixed at 3 L/min, Neonatal: Fixed at 4 L/min
- Means of Inspiratory Triggering: Flow Trigger Control
- Minimum expiratory time: 20% of cycle time; 0.2 to 0.8 seconds
- Oxygen Mixer Accuracy: ± (volume fraction of 2.5% + 2.5% of actual reading)
- Preoperational Checks: Tightness test, Flow Sensor/O2 sensor/CO2 sensor calibration
Features:
- Temperatures from -15°C to +50°C
- Ingress protection IP54
- Maximum altitude of 7.620 meters
- Rugged reinforced housing with impact protection and vibration-proofing
- Shock-resistant, antireflective display
- Approvals and certificates for use in ambulances, helicopters, and airplanes
- Adult, pediatric, and neonatal ventilation (w/neomode option)
- Independence from gas cylinders or compressors
- More than 9 hours of battery operating time
- Noninvasive ventilation and integrated high-flow oxygen therapy
- Advanced ventilation modes, including ASV® – Adaptive Support Ventilation
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.